Embedded PVE Diverter (Solar X)

Issues and solutions related to the Mixergy Solar X's Embedded Solar Diverter.

Installing the Current Reader for Solar X Integration

Issue: Solar diverter not registering current / cylinder switching immersion to full power
Solution: Proper clamp installation and software setup

Steps

  1. Clamp must go around the incoming neutral cable—arrow toward fuse.
  2. Mount the reader within 200mm of mains cable.
  3. Connect reader directly to diverter via RJ-45.
  4. In the Mixergy App, enable "Use spare PV to heat tank".

Important: Confirm clamp orientation and secure connections before testing.

Rapidly Flashing Red Light on Cylinder Controller

Issue: Cylinder unable to detect the current reader.

Solution: Check wiring between the cylinder controller, diverter, and current clamp.